Calculator: Ideal quantization noise

Enter the labelled inputs to calculate: RMS value (V); Value SNR (dB).

RMS value (V)
0.001127637245
Value SNR (dB)
49.9257119

How the calculation works

σq=(Vref/2ᴺ)/√12; SNR=20log₁₀(2ᴺ)+10log₁₀(3/2)

Ideal lumped components are assumed. Parasitics, saturation, mutual inductance, losses and switching ripple are excluded unless explicitly included in the formula.

Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Frequently asked questions

How is the result calculated?

σq=(Vref/2ᴺ)/√12; SNR=20log₁₀(2ᴺ)+10log₁₀(3/2)

What assumptions apply?

Ideal lumped components are assumed. Parasitics, saturation, mutual inductance, losses and switching ripple are excluded unless explicitly included in the formula.

How precise are the displayed results?

Numerical results show up to ten significant digits. Rounding does not improve the accuracy of the input measurements or the model. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Also try:

Back to category →