Gas Heating from Entered Area and Heat Demand

Calculate using the labelled inputs: Gas Heating from Entered Area and Heat Demand.

Annual useful heat (kWh)
12000
Annual gas energy input (kWh)
12631.57895
Estimated annual gas volume (m³)
1203.007519
Rounded variable annual charge
3609.02
Total annual charge
3609.02
Rounded annual charge / 12
300.75
Total charge per useful kWh
0.3007516667

Calculation and assumptions

useful=area·annual_specific_demand; input=useful/(efficiency/100); volume=input/entered_kWh_per_m3; total=round(volume·price_per_m3,2)+annual_fixed.

An entered-demand scenario, not a building assessment, measured bill or equipment sizing calculation. No insulation class or official heat-demand norm is selected automatically. Efficiency is an entered conversion factor; its calorific basis must agree with the entered gas energy per m³. No certified boiler performance is implied. Demand already represents annual useful heat; do not apply hours or days again. Inputs allow six decimals, annual fixed charge two. Variable charge rounds once to cents, halves away from zero. Monthly result is an annual average, not seasonal use. Zero demand keeps fixed charge and makes charge/useful-kWh undefined. No current tariffs, taxes or subsidy eligibility supplied. In one chosen two-decimal currency; no taxes or current market rates are supplied.

Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Frequently asked questions

How is the result calculated?

useful=area·annual_specific_demand; input=useful/(efficiency/100); volume=input/entered_kWh_per_m3; total=round(volume·price_per_m3,2)+annual_fixed.

What assumptions apply?

An entered-demand scenario, not a building assessment, measured bill or equipment sizing calculation. No insulation class or official heat-demand norm is selected automatically. Efficiency is an entered conversion factor; its calorific basis must agree with the entered gas energy per m³. No certified boiler performance is implied. Demand already represents annual useful heat; do not apply hours or days again. Inputs allow six decimals, annual fixed charge two. Variable charge rounds once to cents, halves away from zero. Monthly result is an annual average, not seasonal use. Zero demand keeps fixed charge and makes charge/useful-kWh undefined. No current tariffs, taxes or subsidy eligibility supplied. In one chosen two-decimal currency; no taxes or current market rates are supplied.

How precise are the results?

Monetary totals use two decimal places with the stated rounding rule; other numbers show up to ten significant digits. Display precision does not improve input accuracy. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.