Unit converter
Convert units across thirteen quantity groups, from length and temperature to energy and digital data.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
US and UK liquid measures are distinct. KB means 1000 B, KiB 1024 B. Calorie definitions are labelled separately. Duration months and years are fixed averages, not calendar intervals.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
One sign applies to the entire compound length. Feet must be nonnegative whole numbers; inches may be nonnegative decimals and may exceed 12. Conversion factors are exact. The compound display rounds absolute total inches to the nearest 0.1 in, halves upward, then carries 12 inches into a foot. Decimal unit conversion retains signed input; displayed numeric results have up to 12 significant digits.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. y=x·aᵢ/aⱼ.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. y=x·aᵢ/aⱼ.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. K=°C+273.15; °F=°C·9/5+32; K≥0.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. y=x·aᵢ/aⱼ.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Mach = speed / entered sound speed. The initial 343 m/s is an editable example, not a universal sound speed. Leave it blank to hide Mach; it must be positive when supplied. ft/s uses the international foot.
v=d/t; d=vt; t=d/v. Trip modes use nonnegative values and positive divisors. Enter pace in decimal minutes per kilometre. In component duration, hours and minutes are whole numbers; minutes and seconds are below 60. Clock displays round to the nearest second, with exact halves upward. Finish projections assume constant speed. Optional arrival uses your entered departure and reports a day offset; it does not account for dates, time zones, daylight saving changes or traffic.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. y=x·aᵢ/aⱼ.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs. y=x·aᵢ/aⱼ.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
A duration year is 365.25 days and an average month is one twelfth of it (30.4375 days). These are fixed durations, not dates or calendar arithmetic.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Decimal kB, MB, GB and TB use powers of 1000. Binary KiB, MiB, GiB and TiB use powers of 1024. One byte is 8 bits. Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
Resistive pairs use P=UI=I²R=U²/R; zero divisors are invalid and an undetermined resistance is hidden. AC active power uses UI·cosφ, with 0≤cosφ≤1; U/I is not labelled resistance in this mode. Mechanical power is Fv or M·RPM·π/30; signs share one direction convention, and inverse divisors cannot be zero. Decimal π is approximate. Efficiency uses 0≤Pout≤Pin and Pin>0; unit conversion and energy costs in this mode refer to input power. Enter your own tariff, daily hours and month/year lengths; all costs use the entered currency. A blank tariff hides costs; zero tariff gives zero cost. Mechanical hp and metric PS are different units.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
F=ma; m=F/a; a=F/m; W=mg. Mass cannot be negative; inverse formulas require a nonzero divisor and a nonnegative calculated mass. Force and acceleration may be signed. Enter gravity and reference gravity explicitly; kgf uses standard gravity 9.80665 m/s².
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
ρ=m/V; m=ρV; V=m/ρ. Enter kg, m³ and kg/m³ in formula modes. Mass and density cannot be negative; a divisor must be positive. Unit conversion retains signed values.
How is the result calculated?
Convert units across thirteen quantity groups, from length and temperature to energy and digital data.
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs.
Enter a valid dot-decimal number and select a supported unit. Check positive denominators and absolute temperature.
US and UK liquid measures are distinct. KB means 1000 B, KiB 1024 B. Calorie definitions are labelled separately. Duration months and years are fixed averages, not calendar intervals.
Frequently asked questions
How is the result calculated?
y=x·aᵢ/aⱼ; K=°C+273.15; °F=°C·9/5+32.
How are numbers displayed?
Select the input unit. Results are rounded to 12 significant digits; measurement accuracy depends on your inputs.